關鍵詞:水處理係統 檢測儀表 監控係統 suizhewoguogaigekaifangzhengcedeshenhuaheguowaidaikuanxiangmudebuduanzengduo,jisuanjicekongguanlixitongyipubianjinrujingshuichangzidonghualingyu。muqian,guoneijingshuichangzikongxitongcaiyongzuiduodeshiyougongyejisuanji(IPC)+可編程序邏輯控製器(PLC)+自動化儀表組成的多級分布式計算機測控管理係統。 一 自動化儀表在水處理係統中的重要地位 zaixiandaihuadejingshuichangzhong,meiyigeshengchanguochengzongshiyuxiangyingdeyibiaojizikongjishuyouguan。yibiaonenglianxujiancegegongyicanshu,genjuzhexiecanshudeshujujinxingshoudonghuozidongkongzhi,congerxietiaogongxuzhijian、係統各組成部分之間、各水處理工藝之間的關係,以便使各種設備與設施得到更充分、helideshiyong。tongshi,youyujianceyibiaocedingdeshuzhiyushedingzhikelianxujinxingbijiao,fashengpianchashi,lijijinxingtiaozheng,congerbaozhengshuichulizhiliang。genjuyibiaojiancedecanshu,nengjinyibuzidongtiaojiehekongzhiyaojitoujialiang,baozhengshuibengjizudeheliyunxing,shiguanligengjiakexuehua,dadaojingjiyunxingdemude。youyuyibiaojuyoulianxujiance、越yue限xian報bao警jing的de功gong能neng,便bian於yu及ji時shi處chu理li事shi故gu。儀yi表biao還hai是shi實shi現xian計ji算suan機ji控kong製zhi的de前qian提ti條tiao件jian。所suo以yi在zai先xian進jin的de水shui處chu理li係xi統tong中zhong,自zi動dong化hua儀yi表biao具ju有you非fei常chang重zhong要yao的de作zuo用yong。 二 水處理係統常用儀表的分類 給水工程所用儀表大致可分為兩大類:一類屬於監測生產過程物理參數的儀表,如檢測溫度、壓力、液位、流量等。這類儀表采用國產表,其性能和質量基本能滿足要求。另一類屬於檢測水質的分析儀表,如檢測水的濁度、pH值、溶氧含量、餘氯、SCD值等。這些專用儀表在我國發展比較晚,因此,通常選用國外先進產品,從長遠觀點看是比較經濟、可靠的。 檢測儀表的好壞直接關係到給水自動化的效果。在工程設計過程中,從儀表的性能、質量、價格、備件情況、售後服務等方麵進行反複比較,我們一般采用進口儀表和國產儀表相結合的方法。 三 淨水廠監控係統的構成模式及監測參數 1. 淨水廠監控係統的構成模式 淨水廠的監控係統一般由水廠管理層和現場監控層兩級係統構成,按集中管理、分散控製的原則進行監控。在工程設計中,將廠級計算機係統(即主站)設在水廠中心控製室,各現場監控站(即分站)的數量和位置按工藝流程及構築物的位置、分散程度來定。一般地表水廠現場分站的設置是:進水泵房分站、反應沉澱與加氯加藥分站、過濾分站、送水泵房及變配電室分站、汙泥處理分站。各監測儀表的數據均送到計算機係統,可在監控站的工控機上顯示、控製並打印、記錄、報警。 2. 各分站監測參數 a. 進水泵房分站監測參數 水質參數:源水濁度、pH值、水溫、溶解氧等。 運行參數:調節池水位、吸水井水位、源水流量、泵機分電量、泵站總電量等。 b. 反應沉澱、加氯加藥分站 水質參數:沉澱池出口濁度、濾後餘氯、SCD值。 運行參數:沉澱池水位、沉澱前流量、攪拌罐液位、藥池液位、藥液濃度、沉澱池泥位。 c. 過濾分站 水質參數:濾後水濁度、餘氯。 運行參數:濾池水位、水頭損失、反衝洗水流量、衝洗水箱水位。 d. 送水泵房及變配電室分站 水質參數:出廠水流量、餘氯。 運行參數:出廠水壓力、流量、清水池水位、吸水井水位、交流電壓、交流電流、電量等。 e. 汙泥處理分站 運行參數:回流池水位、水量、濃縮池水位、回流水濁度。 四 水處理係統常用儀表在選型及設計中應注意的問題 1. 儀表選配的一般要求 (1)精確度:是指在正常使用條件下,儀表測量結果的準確程度,誤差越小,精確度越高。 生產過程物理檢測儀表的精確度為±1%,水質分析儀表的精確度為±2%(測高濁水的濁度儀的精確度為±5%)。 (2)響應時間:當(dang)對(dui)被(bei)測(ce)量(liang)進(jin)行(xing)測(ce)量(liang)時(shi),儀(yi)表(biao)指(zhi)示(shi)值(zhi)總(zong)要(yao)經(jing)過(guo)一(yi)段(duan)時(shi)間(jian)才(cai)能(neng)顯(xian)示(shi)出(chu)來(lai),這(zhe)段(duan)時(shi)間(jian)即(ji)為(wei)儀(yi)表(biao)的(de)響(xiang)應(ying)時(shi)間(jian)。一(yi)隻(zhi)儀(yi)表(biao)能(neng)不(bu)能(neng)盡(jin)快(kuai)反(fan)應(ying)出(chu)參(can)數(shu)變(bian)化(hua)的(de)情(qing)況(kuang),是(shi)很(hen)重(zhong)要(yao)的(de)指(zhi)標(biao)。對(dui)水(shui)質(zhi)分(fen)析(xi)儀(yi)表(biao)要(yao)求(qiu)的(de)響(xiang)應(ying)時(shi)間(jian)應(ying)不(bu)超(chao)過(guo)3min。 (3)輸出信號:儀表的模擬輸出應是4~20mA DC信號,負載能力不小於600Ω。 (4)儀表的防護等級應滿足所在環境的要求,一般應不低於IP65,用於藥劑投加係統的檢測儀表要求能耐腐蝕。 (5)四線製的儀表電源多為220V AC、50Hz,兩線製的儀表電源為24V DC。 (6)現場監測儀表宜選用數顯儀。 (7)儀表的工作電源應獨立,不應和計算機共用電源,以保證發生故障和檢修時電源互不幹擾,使各自都能穩定可靠地運行。 (8)weishijisuanjinengjiancedaodianyahuganqihedianliuhuganqideyichangxinhaobingbaojing,shejixuanpeidedianyajidianliubiansongqideshuruxinhaoyingbidianliujidianyahuganqida,jifenbiewei0~6A及0~120V。 (9)應選擇能夠提供可靠服務和有豐富經驗的儀表生產廠商。 2. 水位測量 選擇液位計時應考慮以下因素:(1)測量對象,如被測介質的物理和化學性質,以及工作壓力和溫度、安裝條件、液位變化的速度等;(2)測量和控製要求,如測量範圍、測量(或控製)精確度、顯示方式、現場指示、遠距離指示、與計算機的接口、安全防腐、可靠性及施工方便性。 給水工程中常用的液位計及選型要點如下: a. 浮球式液位計 在(zai)液(ye)體(ti)中(zhong)放(fang)入(ru)一(yi)個(ge)空(kong)心(xin)的(de)浮(fu)球(qiu),當(dang)液(ye)位(wei)變(bian)化(hua)時(shi),浮(fu)球(qiu)將(jiang)產(chan)生(sheng)與(yu)液(ye)位(wei)變(bian)化(hua)相(xiang)同(tong)的(de)位(wei)移(yi)。可(ke)用(yong)機(ji)械(xie)或(huo)電(dian)的(de)方(fang)法(fa)來(lai)測(ce)得(de)浮(fu)球(qiu)的(de)位(wei)移(yi),其(qi)精(jing)確(que)度(du)為(wei)±(1~2)%,這種液位計不適用於高粘度的液體,其輸出端有開關控製和連續輸出。 在淨水廠的設計中,多將此種液位計用於集水井的液位測量以控製排水泵的自動開停。 b.靜壓(或差壓)式液位計 由(you)於(yu)液(ye)柱(zhu)的(de)靜(jing)壓(ya)與(yu)液(ye)位(wei)成(cheng)正(zheng)比(bi),因(yin)此(ci)利(li)用(yong)壓(ya)力(li)表(biao)測(ce)量(liang)基(ji)準(zhun)麵(mian)上(shang)液(ye)柱(zhu)的(de)靜(jing)壓(ya)就(jiu)可(ke)測(ce)得(de)液(ye)位(wei)。根(gen)據(ju)被(bei)測(ce)介(jie)質(zhi)的(de)密(mi)度(du)及(ji)液(ye)體(ti)測(ce)量(liang)範(fan)圍(wei)計(ji)算(suan)出(chu)壓(ya)力(li)或(huo)壓(ya)差(cha)範(fan)圍(wei),再(zai)選(xuan)用(yong)量(liang)程(cheng)、精確度等性能合適的壓力表或差壓表。這種液位計的精確度為±(0.5~2)%。 c. 電容式液位計 在容器內插入電極,當液位變化時,電極內部介質改變,電極間(或電極與容器壁之間)的電容也隨之變化,該電容量的變化再轉換成標準化的直流電信號。其精確度為±(0.5~1.5)%。 電容式液位計具有以下優點:傳感器無機械可動部分,結構簡單、可靠;精確度高;檢測端消耗電能小,動態響應快;維護方便,壽命長。缺點是被測液體的介電常數不穩定會引起誤差。電容式液位計一般用於調節池、清水池等的液位測量。 當測量範圍不超過2m時,采用棒狀、板狀、同軸電極;當超過2m時,采用纜式電極。當被測介質為水時,采用帶絕緣層(可用聚乙烯)的電極。 d. 超聲液位計 超聲液位計的傳感器由一對發射、接(jie)收(shou)換(huan)能(neng)器(qi)組(zu)成(cheng)。發(fa)射(she)換(huan)能(neng)器(qi)麵(mian)對(dui)液(ye)麵(mian)發(fa)射(she)超(chao)聲(sheng)波(bo)脈(mai)衝(chong),超(chao)聲(sheng)波(bo)脈(mai)衝(chong)從(cong)液(ye)麵(mian)上(shang)反(fan)射(she)回(hui)來(lai),被(bei)接(jie)收(shou)換(huan)能(neng)器(qi)接(jie)收(shou)。根(gen)據(ju)發(fa)射(she)至(zhi)接(jie)收(shou)的(de)時(shi)間(jian)可(ke)確(que)定(ding)傳(chuan)感(gan)器(qi)與(yu)液(ye)麵(mian)之(zhi)間(jian)的(de)距(ju)離(li),即(ji)可(ke)換(huan)算(suan)成(cheng)液(ye)位(wei)。其(qi)精(jing)確(que)度(du)為(wei)±0.5%。 這種液位計無機械可動部分,可靠性高,安裝簡單、方便,屬於非接觸測量,且不受液體的粘度、密度等影響,因此多用於藥池、藥罐、排泥水池等的液位測量。但此種方法有一定的盲區,且價格較貴。 3. 流量測量 liuliangceliangfenweiliangzhong,yizhongyongyuliuliangjiance,canyuguochengkongzhi,yidadaotigaoshengchanzidonghuashuiping,gaishanshengchangongyitiaojian,tigaochanpinzhilianghechanliangdemude。lingyizhongyongyuliuliangdejiliang,bujinjiliangchanpindechanliang,haishigongshuiqiyezhuyaojishujingjizhibiaojisuandeyiju。zaigongshuiqiyezuizhuyaode8項經濟指標中,有3項指標是以流量計測量的數據為基礎的。 流量計的選型應考慮以下因素: (1)任何型號的流量計都必須有國家計量部門檢定的證書方可選用。 (2)流量計本身的壓力損失要小。 (3)根據行業要求,流量計的準確度應不低於2.5級。 (4)安裝現場條件應滿足所選流量計對直管段的要求。 (5)所選流量計應能適應安裝現場環境條件如溫度、濕度、電磁幹擾等。 (6)所選流量計應能適用於待測的液體介質。 目前,在給水工程設計中,采用最多的是電磁流量計和超聲流量計。 a. 電磁流量計 電磁流量計的原理是應用法拉弟電磁感應定律,由傳感器和轉換器組成。 在zai測ce量liang中zhong,液ye體ti本ben身shen為wei導dao體ti,磁ci場chang通tong過guo安an裝zhuang在zai管guan路lu中zhong的de兩liang個ge線xian圈quan產chan生sheng。線xian圈quan由you交jiao流liu或huo直zhi流liu電dian源yuan勵li磁ci,磁ci場chang作zuo用yong於yu管guan道dao內nei流liu動dong的de液ye體ti,在zai管guan道dao中zhong產chan生sheng一yi個ge與yu被bei測ce流liu體ti平ping均jun流liu速suV相對應的電壓,且該電壓與流體的流速分布無關。 與管道絕緣的兩個電極監測液體的感應電壓。磁場方向、流體流向及兩個檢測電極的相對位置三者互相垂直。 電磁流量計的優點: (1)測量不受被測液體的溫度、壓力或粘度的影響。 (2)沒有壓力損失。 (3)能連續測量,測量精確度高。 (4)口徑範圍和測量範圍大,測量範圍連續可調。 (5)與流速分布無關。 (6)前後直管段較短,前置直管段為5D(D為儀表的直徑),後置直管段為3D。 (7)穩定性好,輸出為標準化信號,可方便地進入自控係統。 (8)變送器導管內壁有襯裏材料,具備良好的耐腐、耐磨性。 (9)轉換器體積小,消耗功率小,抗幹擾性能強,便於現場觀察。 應(ying)用(yong)於(yu)水(shui)處(chu)理(li)係(xi)統(tong)的(de)電(dian)磁(ci)流(liu)量(liang)計(ji)的(de)襯(chen)裏(li)材(cai)料(liao)多(duo)選(xuan)用(yong)氯(lv)丁(ding)橡(xiang)膠(jiao),因(yin)其(qi)有(you)較(jiao)好(hao)的(de)耐(nai)磨(mo)性(xing)。安(an)裝(zhuang)時(shi)應(ying)注(zhu)意(yi)遠(yuan)離(li)外(wai)界(jie)的(de)電(dian)磁(ci)場(chang)源(yuan),以(yi)免(mian)影(ying)響(xiang)傳(chuan)感(gan)器(qi)的(de)工(gong)作(zuo)磁(ci)場(chang)及(ji)流(liu)量(liang)信(xin)號(hao),傳(chuan)感(gan)器(qi)水(shui)平(ping)安(an)裝(zhuang)時(shi),要(yao)求(qiu)兩(liang)個(ge)電(dian)極(ji)的(de)中(zhong)心(xin)軸(zhou)線(xian)處(chu)於(yu)水(shui)平(ping)狀(zhuang)態(tai),防(fang)止(zhi)顆(ke)粒(li)雜(za)質(zhi)沉(chen)積(ji),影(ying)響(xiang)電(dian)極(ji)工(gong)作(zuo)。測(ce)量(liang)管(guan)內(nei)應(ying)為(wei)滿(man)管(guan),不(bu)允(yun)許(xu)大(da)量(liang)氣(qi)泡(pao)通(tong)過(guo)傳(chuan)感(gan)器(qi),當(dang)不(bu)能(neng)滿(man)足(zu)條(tiao)件(jian)時(shi),應(ying)采(cai)取(qu)相(xiang)應(ying)措(cuo)施(shi)。 為使儀表可靠地工作,提高測量精確度,不受外界寄生電勢的幹擾,傳感器應有良好的單獨接地線,且接地電阻應小於10Ω,youqishianzhuangzaiyinjibaohuguandaoshangshi。ruzaitianjinshuiyuanchangchuchangganguanshanganzhuangdedianciliuliangji,youyuguandaocaiyongleyinjibaohu,fanghudianjiefushideguandaoneibihewaibizhijianshijueyuande,beicejiezhimeiyoujiedidianwei,suoyi,jiangchuanganqijiedihuanzhuangzaichuanganqidelianggeduanmianshang,yulianjieguandaodefalanjueyuan。chuanganqiyujiedihuanyongjiedixianxianglian,bingyinzhijiediji。guandaofalanzhijianyongdianlanxiangliandanbuliandaochuanganqishang。falanlianjieluoshuanyongjueyuanchentaohedianquangeli。gaidianciliuliangjizitouchanshiyongyilai,xiaoguoyizhijiaohao。 轉換器應安裝在符合其防護等級要求的場所,在滿足安裝環境、使用要求的前提下,轉換器與傳感器之間的距離和連接電纜越短越好,以節約投資,減少可能產生的強電信號的幹擾。 b. 超聲流量計 最zui近jin十shi幾ji年nian來lai,由you於yu電dian子zi技ji術shu的de發fa展zhan,超chao聲sheng流liu量liang計ji才cai得de以yi應ying用yong於yu流liu量liang測ce量liang。利li用yong超chao聲sheng流liu量liang計ji進jin行xing測ce量liang的de方fang法fa有you很hen多duo種zhong,其qi中zhong較jiao為wei典dian型xing的de是shi時shi差cha法fa和he多duo普pu勒le法fa。淨jing水shui廠chang多duo選xuan用yong時shi差cha法fa流liu量liang計ji,其qi方fang法fa是shi在zai測ce量liang管guan道dao上shang安an裝zhuang兩liang個ge換huan能neng器qi,因yin順shun流liu與yu逆ni流liu流liu速su差cha別bie的de影ying響xiang,測ce量liang從cong發fa射she到dao接jie收shou而er產chan生sheng的de時shi間jian差cha,據ju此ci測ce出chu流liu速su。 超聲流量計的主要優點: (1)安an裝zhuang維wei護hu方fang便bian。隨sui著zhe夾jia裝zhuang式shi傳chuan感gan器qi的de廣guang泛fan使shi用yong,在zai安an裝zhuang和he維wei護hu超chao聲sheng流liu量liang計ji時shi不bu需xu在zai管guan道dao上shang打da孔kong或huo切qie斷duan流liu量liang,就jiu可ke在zai已yi存cun在zai的de應ying用yong場chang合he很hen方fang便bian地di進jin行xing安an裝zhuang,尤you其qi適shi用yong於yu大da口kou徑jing管guan道dao檢jian測ce係xi統tong。 (2)口徑範圍大,且價格不受管徑影響。 (3)測量可靠性高。 (4)無壓力損失。 (5)不受流體參數影響。 (6)輸出標準化直流信號,可方便地進入自控係統。 選用超聲流量計要特別注意傳感器的安裝誤差、管道內壁結垢、fangfucengjunyunyufou,zhexieyinsuduiceliangjieguoyingxianghenda。lingjuchaoshengliuliangjideceliangyuanli,zhiyouliusufenbujunyunshicainengbaozhengceliangdejingquedu,suoyizailiuliangjideshangxiayouyaoyouzugoudezhiguanduan,cankaogezhongziliaojiliuliangjideshiyongshouce,yaoqiushangyouzuishaobuxiaoyu10D,下遊大於5D。 由you於yu自zi來lai水shui行xing業ye為wei連lian續xu生sheng產chan,進jin行xing不bu間jian斷duan計ji量liang是shi極ji為wei重zhong要yao的de,所suo以yi一yi般ban安an裝zhuang於yu管guan道dao上shang的de流liu量liang計ji不bu能neng經jing常chang拆chai卸xie送song檢jian,一yi般ban做zuo法fa是shi采cai用yong精jing確que度du較jiao高gao的de便bian攜xie式shi超chao聲sheng流liu量liang計ji,按an周zhou期qi送song國guo家jia認ren證zheng單dan位wei進jin行xing校xiao準zhun,作zuo為wei企qi業ye的de標biao準zhun器qi具ju,再zai用yong比bi對dui的de方fang式shi定ding期qi檢jian測ce在zai線xian流liu量liang計ji。這zhe需xu要yao設she計ji人ren員yuan在zai設she計ji時shi應ying根gen據ju使shi用yong單dan位wei要yao求qiu,考kao慮lv將jiang來lai生sheng產chan管guan理li的de需xu要yao,預yu留liu出chu比bi對dui測ce量liang的de空kong間jian,以yi方fang便bian用yong戶hu,即ji將jiang流liu量liang計ji井jing做zuo得de稍shao大da一yi些xie,除chu安an裝zhuang固gu定ding式shi流liu量liang計ji外wai,還hai應ying如ru圖tu1所示預留出便攜式流量計測量的空間。
 4.濁度的測量 濁zhuo度du是shi水shui體ti渾hun濁zhuo程cheng度du的de度du量liang,也ye就jiu是shi水shui體ti中zhong存cun在zai微wei細xi分fen散san的de懸xuan浮fu性xing粒li子zi,使shi水shui透tou明ming度du降jiang低di的de程cheng度du。濁zhuo度du儀yi是shi測ce量liang水shui體ti渾hun濁zhuo程cheng度du的de儀yi器qi,主zhu要yao用yong於yu對dui水shui質zhi的de監jian測ce和he管guan理li。 淨水廠負責供應居民生活用水和工業用水,供水的質量直接涉及人民的健康、安全,以及食品、釀造、醫藥、紡織、印染、電(dian)力(li)等(deng)各(ge)行(xing)各(ge)業(ye)的(de)正(zheng)常(chang)生(sheng)產(chan)和(he)產(chan)品(pin)質(zhi)量(liang)。濁(zhuo)度(du)是(shi)一(yi)項(xiang)很(hen)重(zhong)要(yao)的(de)水(shui)質(zhi)指(zhi)標(biao),因(yin)此(ci)對(dui)濁(zhuo)度(du)儀(yi)的(de)選(xuan)擇(ze)顯(xian)得(de)尤(you)為(wei)重(zhong)要(yao)。濁(zhuo)度(du)儀(yi)可(ke)分(fen)為(wei)目(mu)視(shi)濁(zhuo)度(du)儀(yi)和(he)光(guang)電(dian)濁(zhuo)度(du)儀(yi)兩(liang)大(da)類(lei)。光(guang)電(dian)濁(zhuo)度(du)儀(yi)就(jiu)其(qi)用(yong)途(tu)可(ke)分(fen)為(wei)工(gong)藝(yi)監(jian)控(kong)(連續測定)濁度儀和實驗室(包括便攜式)濁度儀,就其設計原理又可分為透射光濁度儀和散射光濁度儀。 由(you)於(yu)散(san)射(she)光(guang)濁(zhuo)度(du)儀(yi)對(dui)水(shui)的(de)低(di)濁(zhuo)度(du)有(you)較(jiao)高(gao)的(de)靈(ling)敏(min)度(du),準(zhun)確(que)度(du)高(gao),相(xiang)對(dui)誤(wu)差(cha)小(xiao),重(zhong)複(fu)性(xing)好(hao),水(shui)的(de)色(se)度(du)不(bu)顯(xian)示(shi)濁(zhuo)度(du),且(qie)散(san)射(she)光(guang)與(yu)入(ru)射(she)光(guang)強(qiang)度(du)比(bi)可(ke)呈(cheng)線(xian)性(xing)關(guan)係(xi),故(gu)1992年9月世界衛生組織公布的《飲用水水質準則》中規定將散射光濁度儀作為測定儀器。同時,“供水行業2000年技術進步發展規劃”中已明確規定一類水司管網水濁度指標為1NTU。 在淨水廠設計中常用HACH公司的1720D、SS6係列濁度儀(屬於散射光式濁度儀)。 在濾後水及出廠水的測量中,一般采用1720D(原為1720C)係(xi)列(lie)濁(zhuo)度(du)儀(yi)。使(shi)用(yong)時(shi)水(shui)樣(yang)連(lian)續(xu)流(liu)入(ru)濁(zhuo)度(du)儀(yi),流(liu)經(jing)脫(tuo)泡(pao)器(qi)以(yi)排(pai)空(kong)水(shui)流(liu)中(zhong)的(de)氣(qi)泡(pao),然(ran)後(hou)進(jin)入(ru)濁(zhuo)度(du)儀(yi)的(de)中(zhong)柱(zhu)內(nei),上(shang)升(sheng)至(zhi)測(ce)量(liang)室(shi)並(bing)溢(yi)過(guo)其(qi)邊(bian)緣(yuan)進(jin)入(ru)排(pai)放(fang)口(kou)。聚(ju)光(guang)束(shu)從(cong)傳(chuan)感(gan)器(qi)頭(tou)部(bu)組(zu)件(jian)中(zhong)向(xiang)下(xia)投(tou)射(she)到(dao)濁(zhuo)度(du)儀(yi)主(zhu)體(ti)內(nei)的(de)水(shui)樣(yang)中(zhong),浸(jin)在(zai)水(shui)樣(yang)中(zhong)的(de)光(guang)電(dian)管(guan)測(ce)量(liang)水(shui)中(zhong)懸(xuan)浮(fu)固(gu)體(ti)90°方向的散射光,散射光的量與水樣的濁度成正比。1720D不需采用樣品池,這樣可減少雜散光,提高測量準確度。1720D的準確度為:0~40NTU範圍內為±2%,40~100NTU範圍內為±5%,分辨力為0.001NTU,響應時間為75s。 測(ce)量(liang)濾(lv)後(hou)水(shui)的(de)濁(zhuo)度(du)儀(yi)多(duo)安(an)裝(zhuang)於(yu)濾(lv)站(zhan)管(guan)廊(lang)內(nei),可(ke)采(cai)用(yong)壁(bi)掛(gua)或(huo)櫃(gui)裝(zhuang),出(chu)廠(chang)水(shui)的(de)測(ce)量(liang)一(yi)般(ban)在(zai)送(song)水(shui)泵(beng)房(fang)設(she)置(zhi)水(shui)質(zhi)儀(yi)表(biao)間(jian),將(jiang)濁(zhuo)度(du)儀(yi)及(ji)其(qi)他(ta)水(shui)質(zhi)檢(jian)測(ce)儀(yi)表(biao)置(zhi)於(yu)儀(yi)表(biao)間(jian)內(nei),再(zai)將(jiang)信(xin)號(hao)引(yin)至(zhi)監(jian)控(kong)站(zhan)。 雖然1720D的測量範圍為0~ 100NTU,但最好不用其測量濾前水,因為雖然光學上能測到100NTU,但在生產使用上會帶來許多不便。測量源水及濾前水多使用SS6xiliebiaomiansansheshizhuoduyi,tashijiangguangshushezaiyetibiaomian,cedinglaiziyemiandesansheguang,bimianleguangxuexitongyushuiyangzhijiejiechu,xiaochuleqingxiliutongchishidailaidexinhaodiushi,rutu2所示。
 SS6係列的測量範圍為0~9999NTU,一般地表水廠的源水均在此範圍內。它在0~2000NTU範圍內的準確度為±5%,2000~9999NTU範圍內準確度為±10%。 濁zhuo度du儀yi取qu樣yang點dian的de選xuan擇ze應ying與yu工gong藝yi專zhuan業ye緊jin密mi結jie合he,選xuan取qu最zui有you代dai表biao性xing的de點dian,取qu樣yang孔kong最zui好hao不bu要yao開kai在zai被bei取qu樣yang管guan道dao的de頂ding部bu,避bi免mian將jiang管guan道dao中zhong的de氣qi泡pao抽chou進jin取qu樣yang管guan而er影ying響xiang濁zhuo度du儀yi的de測ce量liang準zhun確que度du,水shui樣yang的de提ti取qu最zui好hao用yong小xiao型xing采cai樣yang泵beng取qu樣yang,保bao證zheng取qu樣yang管guan內nei有you一yi定ding流liu速su,不bu易yi在zai管guan道dao內nei壁bi結jie垢gou。取qu樣yang管guan道dao的de口kou徑jing應ying根gen據ju儀yi表biao取qu樣yang水shui的de總zong需xu要yao量liang決jue定ding。 5. 顯示儀表的選用 一yi般ban淨jing水shui廠chang工gong程cheng多duo選xuan用yong智zhi能neng化hua顯xian示shi儀yi表biao,其qi功gong能neng齊qi全quan,能neng進jin行xing數shu字zi信xin號hao處chu理li,實shi現xian控kong製zhi功gong能neng,而er且qie測ce量liang值zhi以yi液ye晶jing顯xian示shi,操cao作zuo方fang便bian,可ke以yi保bao存cun數shu據ju,具ju有you自zi診zhen斷duan功gong能neng。雖sui然ran與yu計ji算suan機ji係xi統tong聯lian網wang後hou,它ta的de優you勢shi沒mei有you完wan全quan發fa揮hui出chu來lai,而er被bei計ji算suan機ji係xi統tong所suo取qu代dai,但dan在zai目mu前qian淨jing水shui廠chang的de建jian設she中zhong,使shi用yong智zhi能neng化hua的de顯xian示shi儀yi表biao作zuo為wei在zai計ji算suan機ji係xi統tong未wei調tiao試shi投tou運yun階jie段duan或huo發fa生sheng故gu障zhang時shi的de輔fu助zhu儀yi表biao,也ye能neng滿man足zu現xian場chang控kong製zhi、顯示的要求。 在某些情況下,同時需要本地顯示與遠程傳送,此時不宜采取信號串聯方式,而應采用信號分配器,即1路輸入,兩路輸出,一路輸出送顯示儀表,另一路輸出可輸入PLC,如常用的WS15242,如圖3所示。
 6. 儀表係統的接地和防雷 接jie地di可ke分fen為wei保bao護hu接jie地di和he工gong作zuo接jie地di。保bao護hu接jie地di是shi為wei避bi免mian工gong作zuo人ren員yuan因yin設she備bei絕jue緣yuan損sun壞huai或huo絕jue緣yuan性xing能neng下xia降jiang時shi遭zao受shou觸chu電dian危wei險xian和he保bao護hu設she備bei的de安an全quan。工gong作zuo接jie地di是shi為wei保bao證zheng儀yi表biao穩wen定ding可ke靠kao地di運yun行xing。一yi般ban淨jing水shui廠chang儀yi表biao係xi統tong的de接jie地di采cai用yongTN-S係統,即3根相線A、B、C,1根中性線N即保護線PE。用電設備的外露可導電部分接到PE線上,其優點是PE線(xian)在(zai)正(zheng)常(chang)工(gong)作(zuo)時(shi)不(bu)呈(cheng)現(xian)電(dian)流(liu),因(yin)此(ci)設(she)備(bei)的(de)外(wai)露(lu)可(ke)導(dao)電(dian)部(bu)分(fen)不(bu)呈(cheng)現(xian)對(dui)地(di)電(dian)壓(ya)而(er)且(qie)在(zai)事(shi)故(gu)時(shi)也(ye)容(rong)易(yi)切(qie)斷(duan)電(dian)源(yuan),有(you)較(jiao)強(qiang)的(de)電(dian)磁(ci)適(shi)應(ying)性(xing),避(bi)免(mian)了(le)高(gao)次(ci)諧(xie)波(bo)的(de)幹(gan)擾(rao)。 工gong作zuo接jie地di的de原yuan則ze是shi單dan點dian接jie地di。由you於yu對dui地di電dian位wei差cha的de存cun在zai,如ru果guo出chu現xian一yi個ge以yi上shang的de接jie地di點dian就jiu會hui形xing成cheng地di回hui路lu,將jiang幹gan擾rao引yin入ru儀yi表biao中zhong,所suo以yi,同tong一yi信xin號hao回hui路lu、同一屏蔽層隻能有一個接地點。 儀表工作接地可單獨設置或與保護接地共用同一接地體。從工程實踐經驗來看,接地電阻一般應不超過1Ω。 一般淨水廠設施分散,構築物低矮,地形平坦、空(kong)曠(kuang),特(te)別(bie)是(shi)有(you)些(xie)流(liu)量(liang)計(ji)井(jing)位(wei)於(yu)廠(chang)區(qu)之(zhi)外(wai),在(zai)這(zhe)種(zhong)情(qing)況(kuang)下(xia),儀(yi)表(biao)設(she)備(bei)的(de)被(bei)雷(lei)擊(ji)率(lv)增(zeng)加(jia)。在(zai)實(shi)踐(jian)中(zhong),筆(bi)者(zhe)多(duo)次(ci)遇(yu)到(dao)過(guo)雷(lei)擊(ji)損(sun)壞(huai)儀(yi)表(biao)或(huo)儀(yi)表(biao)不(bu)明(ming)原(yuan)因(yin)損(sun)壞(huai)的(de)事(shi)件(jian)。因(yin)此(ci),安(an)裝(zhuang)品(pin)質(zhi)優(you)良(liang),動(dong)作(zuo)可(ke)靠(kao)的(de)避(bi)雷(lei)器(qi),是(shi)不(bu)可(ke)缺(que)少(shao)的(de)保(bao)護(hu)措(cuo)施(shi),如(ru)采(cai)用(yong)德(de)國(guo)Pepperl+Fuchs公司的ESP係列避雷柵用於流量計的信號和電源的保護,效果良好。 五 總結 (1)要實現淨水廠的現代化管理,必須使用自動化儀表。 (2)設計人員應站在用戶的角度上,為用戶著想,在設計與選用儀表時,應做到:穩定可靠,操作簡單,安裝方便,物美價廉,連續測量,反應靈敏,互換性強,便於維護。 (3)設計人員平時應注意技術資料的收集、整理,以便於消化吸收。 (4)淨(jing)水(shui)廠(chang)建(jian)成(cheng)通(tong)水(shui),儀(yi)表(biao)正(zheng)確(que)投(tou)入(ru)使(shi)用(yong)後(hou),設(she)計(ji)人(ren)員(yuan)應(ying)多(duo)下(xia)現(xian)場(chang),對(dui)儀(yi)表(biao)的(de)使(shi)用(yong)情(qing)況(kuang)做(zuo)跟(gen)蹤(zong)調(tiao)查(zha),了(le)解(jie)儀(yi)表(biao)的(de)工(gong)作(zuo)情(qing)況(kuang),及(ji)時(shi)總(zong)結(jie)經(jing)驗(yan),以(yi)利(li)於(yu)今(jin)後(hou)的(de)設(she)計(ji)工(gong)作(zuo)日(ri)趨(qu)完(wan)善(shan)。
|
|
狀 態:
離線
公司簡介
產品目錄
供應信息
|
|
|
公司名稱:
|
江蘇華海測控技術有限公司
|
| 聯 係 人: |
呂海東
|
| 電 話: |
0517-6981686
|
| 傳 真: |
05176981010 |
| 地 址: |
江蘇省金湖縣工業園區新興路 |
| 郵 編: |
211600 |
| 主 頁: |
|
|
|
|
|