|
yiliaofanghutixizhong,kouzhaodefanghuxingnengshishouhushiyongzhejiankangdeguanjianfangxian,erqitijiaohuanyalichazuoweihengliangkouzhaofanghuxingnengdehexinzhibiao,qijiancezhiguanzhongyao。yihanyiqiyiyongkouzhaoqitijiaohuanyalichaceshiyipingjiexianjinjishuyusheji,chengweibaozhangkouzhaozhiliangjiancededelizhushou,guifancaozuohezhengqueshiyonggaiyiqi,shihuoqukekaojianceshujudezhongyaoqianti。
易(yi)焓(han)儀(yi)器(qi)醫(yi)用(yong)口(kou)罩(zhao)氣(qi)體(ti)交(jiao)換(huan)壓(ya)力(li)差(cha)測(ce)試(shi)儀(yi)的(de)工(gong)作(zuo)原(yuan)理(li)根(gen)植(zhi)於(yu)流(liu)體(ti)力(li)學(xue),通(tong)過(guo)高(gao)度(du)還(hai)原(yuan)人(ren)體(ti)呼(hu)吸(xi)時(shi)氣(qi)體(ti)穿(chuan)透(tou)口(kou)罩(zhao)的(de)真(zhen)實(shi)過(guo)程(cheng),測(ce)量(liang)口(kou)罩(zhao)兩(liang)側(ce)的(de)壓(ya)力(li)差(cha)值(zhi)。儀(yi)器(qi)由(you)穩(wen)定(ding)供(gong)氣(qi)的(de)氣(qi)源(yuan)係(xi)統(tong)、靈(ling)敏(min)的(de)壓(ya)力(li)測(ce)量(liang)係(xi)統(tong),以(yi)及(ji)穩(wen)固(gu)可(ke)靠(kao)的(de)樣(yang)品(pin)夾(jia)持(chi)裝(zhuang)置(zhi)等(deng)核(he)心(xin)部(bu)分(fen)構(gou)成(cheng)。氣(qi)源(yuan)係(xi)統(tong)可(ke)按(an)需(xu)提(ti)供(gong)不(bu)同(tong)流(liu)量(liang)的(de)穩(wen)定(ding)氣(qi)流(liu),逼(bi)真(zhen)模(mo)擬(ni)實(shi)際(ji)呼(hu)吸(xi)場(chang)景(jing);壓力測量係統能夠快速且地捕捉口罩兩側的壓力數據;樣yang品pin夾jia持chi裝zhuang置zhi則ze采cai用yong特te殊shu設she計ji,確que保bao口kou罩zhao樣yang品pin在zai測ce試shi過guo程cheng中zhong穩wen固gu無wu位wei移yi,從cong根gen源yuan上shang杜du絕jue因yin樣yang品pin鬆song動dong導dao致zhi的de檢jian測ce誤wu差cha。在zai開kai啟qi測ce試shi工gong作zuo前qian,必bi須xu嚴yan格ge完wan成cheng儀yi器qi的de校xiao準zhun與yu檢jian查zha流liu程cheng。
xiaozhunshiquebaoceshijieguodudejishi,xuyangeyizhaoyihanyiqifudaidexiaozhunguicheng,jiezhubiaozhunyaliyuanduiyaliceliangxitongjinxingxizhixiaozhun。tongshi,quanmianjianzhaqiyuanxitongdeqitiliuliangwendingxing,yijiyangpinjiachizhuangzhidewanzhengxing,renhexiweishuloudoukenengduijiancejieguochanshengzhongdayingxiang。
具體操作流程如下:首先,將待測醫用口罩平整妥帖地置於樣品夾持裝置上,仔細檢查口罩邊緣與夾持裝置的貼合程度,確保無縫隙、無漏氣;接著,依據現行測試標準,將氣源係統的氣體流量設定為常見的 85L/min 等標準數值;隨後,啟動儀器,耐心等待係統運行穩定後,迅速讀取並詳細記錄口罩兩側的壓力差數據;,為wei保bao證zheng結jie果guo的de可ke靠kao性xing,需xu重zhong複fu上shang述shu測ce試shi步bu驟zhou多duo次ci,取qu其qi平ping均jun值zhi作zuo為wei最zui終zhong的de測ce試shi結jie論lun。日ri常chang使shi用yong過guo程cheng中zhong,易yi焓han儀yi器qi醫yi用yong口kou罩zhao氣qi體ti交jiao換huan壓ya力li差cha測ce試shi儀yi的de維wei護hu保bao養yang同tong樣yang不bu容rong小xiao覷qu。
定期對樣品夾持裝置進行深度清潔,及時清除可能幹擾測試的灰塵與雜質;密切關注氣源係統過濾器的使用狀況,一旦發現堵塞立即更換,保障氣體的純淨度;
ciwai,anzhaoyiqishiyongzhouqi,dingqikaizhanquanmiandexingnengjianceyuweihugongzuo,quebaoyiqishizhongbaochidegongzuozhuangtai。yihanyiqiyiyongkouzhaoqitijiaohuanyalichaceshiyishiyiyongkouzhaozhiliangbakonghuanjiezhongdeguanjianshebei,weiyouyangezunxunguifanjinxingshiyongyuweihu,fangnenghuoqu、可靠的測試數據,為醫用口罩的品質保障構築堅實防線。
|