dianciliuliangjixianrujinyingyongdelingyuyuelaiyueduole,henduorenyedouzaijijidexuexiyouguandianciliuliangjidezhishi,xiamianjiudaidajialejieyixiadianciliuliangjizaixianxiaozhundefangfa。
電磁流量計出廠時其精確度已經過標定線標定。但在使用現場,由於受環境條件、流liu體ti特te性xing以yi及ji儀yi表biao本ben身shen如ru元yuan器qi件jian損sun壞huai等deng原yuan因yin引yin起qi儀yi表biao運yun行xing故gu障zhang等deng情qing況kuang,對dui於yu長chang期qi使shi用yong後hou的de流liu量liang計ji有you必bi要yao進jin行xing一yi次ci常chang規gui的de現xian場chang校xiao準zhun。由you於yu電dian磁ci流liu量liang計ji的de傳chuan感gan器qi安an裝zhuang在zai管guan道dao上shang,難nan以yi拆chai下xia送song至zhi標biao定ding線xian進jin行xing檢jian查zha,而er目mu前qian在zai流liu量liang計ji量liang範fan圍wei內nei,國guo家jia和he地di方fang對dui大da口kou徑jing流liu量liang計ji尚shang未wei有you現xian場chang條tiao件jian下xia進jin行xing在zai線xian檢jian驗yan的de規gui程cheng和he其qi它ta法fa規gui文wen件jian。為wei了le保bao證zheng電dian磁ci流liu量liang計ji在zai故gu障zhang修xiu複fu後hou以yi及ji長chang期qi使shi用yong後hou的de精jing度du和he可ke靠kao性xing,而er又you不bu影ying響xiang日ri常chang生sheng產chan,推tui出chu以yi下xia幾ji點dian在zai線xian校xiao準zhun方fang法fa:
1、對電磁流量計勵磁線圈進行安全絕緣測試,應大於20MΩ。
2、對電磁流量計勵磁線圈進行銅電阻測試,應與原出廠值相同(環境溫度相同時)。
3、對電磁流量計傳感器電極對地電阻進行測試,若電阻值在2一20kf之間,並伴有充放電現象,兩隻電極的電阻相近,則認為好的。
4、對電磁流量計轉換器勵磁電流進行測試,觀察其輸出與轉換器原電流的值,誤差不超過士0.25mA。
5、對電磁流量計轉換器模擬量輸出及頻率輸出進行測試,觀察其線性變化情況,並計算其最大線性誤差,應不超過士0.5%。
6、對DN 1200mm以上的電磁流量計,應測試推動級NB,電流誤差不超過12mA。
|